{"id":20443,"date":"2026-05-19T16:13:23","date_gmt":"2026-05-19T14:13:23","guid":{"rendered":"https:\/\/hayaenergy.com\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/"},"modified":"2026-05-19T16:20:45","modified_gmt":"2026-05-19T14:20:45","slug":"black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations","status":"publish","type":"post","link":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/","title":{"rendered":"Black-out de la p\u00e9ninsule Ib\u00e9rique du 28 avril : nouvelles informations"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>Trois rapports analysent le black-out du 28 avril en Espagne : que r\u00e9v\u00e8lent-ils ?<\/strong><\/p>\n<p style=\"text-align: justify;\">En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril. Le premier \u00e9mane du minist\u00e8re de la Transition \u00e9cologique et du D\u00e9fi d\u00e9mographique (MITECO) le 17 juin. Le lendemain, Red El\u00e9ctrica de Espa\u00f1a (REE) a publi\u00e9 son rapport, suivi le 23 juin par celui de l\u2019Association des entreprises \u00e9lectriques (AELEC). Deux autres rapports restent encore attendus : l\u2019un de la Commission nationale des march\u00e9s et de la concurrence (CNMC), et l\u2019autre d\u2019ENTSO-E.<\/p>\n<p style=\"text-align: justify;\"><strong>Oscillations de fr\u00e9quence : le pr\u00e9lude au black-out<\/strong><\/p>\n<p style=\"text-align: justify;\">Les trois rapports s\u2019accordent sur les oscillations de fr\u00e9quence enregistr\u00e9es sur le r\u00e9seau durant la matin\u00e9e pr\u00e9c\u00e9dant le black-out. Les premi\u00e8res oscillations, d\u2019environ 0,2 Hz, semblent avoir une origine naturelle. Selon REE, elles sont compatibles avec une oscillation interzones du syst\u00e8me \u00e9lectrique europ\u00e9en synchronis\u00e9. Le rapport d\u2019AELEC pr\u00e9cise que ces variations du mix correspondent \u00e0 une r\u00e9duction du nombre de centrales \u00e0 cycle combin\u00e9 connect\u00e9es au syst\u00e8me et que, par cons\u00e9quent, ces oscillations pourraient \u00eatre li\u00e9es au programme de production de cette journ\u00e9e.<\/p>\n<p style=\"text-align: justify;\">Dans tous les cas, ces premi\u00e8res perturbations ont \u00e9t\u00e9 absorb\u00e9es par le r\u00e9seau sans n\u00e9cessiter de mesures correctives significatives de la part de REE.<\/p>\n<p style=\"text-align: justify;\"><strong>Le premier choc majeur : 12h03<\/strong><\/p>\n<p style=\"text-align: justify;\">\u00c0 12h03, une oscillation d\u2019une plus grande ampleur (0,6 Hz) a \u00e9t\u00e9 enregistr\u00e9e. Elle a dur\u00e9 4 minutes et 42 secondes, affaiblissant la capacit\u00e9 du syst\u00e8me \u00e0 amortir les perturbations. Cette oscillation, class\u00e9e comme forc\u00e9e et de nature locale, aurait pris naissance \u2014 selon le rapport de REE \u2014 dans une centrale photovolta\u00efque situ\u00e9e dans la province de Badajoz.<\/p>\n<p style=\"text-align: justify;\">En r\u00e9ponse, REE a activ\u00e9 plusieurs mesures :<\/p>\n<ul style=\"text-align: justify;\">\n<li>R\u00e9duction des \u00e9changes exportateurs avec la France de 800 MW, fixant le programme \u00e0 1 500 MW dans le sens exportateur.<\/li>\n<li>Modification du mode d\u2019exploitation de l\u2019interconnexion HVDC avec la France en puissance constante (objectif : 1 000 MW de l\u2019Espagne vers la France).<\/li>\n<li>Renforcement du r\u00e9seau par la connexion de cinq circuits 400 kV qui \u00e9taient d\u00e9connect\u00e9s afin de r\u00e9duire l\u2019imp\u00e9dance du syst\u00e8me.<\/li>\n<li>Ouverture de r\u00e9actances afin de contrer la chute de tension provoqu\u00e9e par les oscillations.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong>Une situation de plus en plus tendue<\/strong><\/p>\n<p style=\"text-align: justify;\">Malgr\u00e9 ces actions correctives, une nouvelle oscillation de 0,6 Hz s\u2019est produite \u00e0 12h16, provoquant de nouvelles chutes de tension sur le r\u00e9seau. En cons\u00e9quence, davantage de r\u00e9actances ont \u00e9t\u00e9 activ\u00e9es.<\/p>\n<p style=\"text-align: justify;\">\u00c0 12h19, une autre oscillation a \u00e9t\u00e9 enregistr\u00e9e, avec une fr\u00e9quence plus faible (0,2 Hz), mais caract\u00e9ris\u00e9e par une amplitude beaucoup plus importante que les pr\u00e9c\u00e9dentes (jusqu\u2019\u00e0 200 mHz). L\u2019origine de cette oscillation est attribu\u00e9e \u00e0 une oscillation interzones d\u00e9riv\u00e9e du mode continental Est-Centre-Ouest du syst\u00e8me \u00e9lectrique europ\u00e9en.<\/p>\n<p style=\"text-align: justify;\">En r\u00e9ponse \u00e0 cette nouvelle perturbation, de nouvelles mesures ont \u00e9t\u00e9 prises :<\/p>\n<ul style=\"text-align: justify;\">\n<li>Nouvelles connexions de lignes 400 kV pour r\u00e9duire l\u2019imp\u00e9dance.<\/li>\n<li>R\u00e9duction des \u00e9changes exportateurs avec la France \u00e0 1 000 MW (le lien HVDC exportant d\u00e9j\u00e0 1 000 MW de l\u2019Espagne vers la France, cela impliquait un solde nul sur les lignes AC). Cela repr\u00e9sente une r\u00e9duction totale des \u00e9changes de 1 300 MW.<\/li>\n<li>R\u00e9duction des \u00e9changes exportateurs avec le Portugal de 2 545 MW \u00e0 2 000 MW.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">\u00c0 12h22, une fois la fr\u00e9quence stabilis\u00e9e, la tension a commenc\u00e9 \u00e0 augmenter dans les marges d\u2019exploitation. En r\u00e9ponse, REE a initi\u00e9 le couplage de r\u00e9acteurs dans diff\u00e9rentes sous-stations afin de ralentir cette hausse.<\/p>\n<p style=\"text-align: justify;\">REE souligne que, contrairement aux premi\u00e8res oscillations, ces derni\u00e8res n\u2019\u00e9taient pas d\u2019origine naturelle mais \u00ab forc\u00e9es \u00bb. Son analyse pointe \u00e0 nouveau une centrale photovolta\u00efque situ\u00e9e \u00e0 Badajoz comme d\u00e9clencheur possible.<\/p>\n<p style=\"text-align: justify;\"><strong>Les mesures correctives ont-elles affaibli le syst\u00e8me ?<\/strong><\/p>\n<p style=\"text-align: justify;\">L\u2019une des questions cl\u00e9s est de savoir si les actions de mitigation elles-m\u00eames auraient pu, paradoxalement, rendre le syst\u00e8me plus vuln\u00e9rable aux perturbations suivantes.<\/p>\n<p style=\"text-align: justify;\">Cette hypoth\u00e8se est fortement soutenue dans le rapport d\u2019AELEC, qui estime m\u00eame l\u2019augmentation de g\u00e9n\u00e9ration r\u00e9active provoqu\u00e9e par ces mesures \u00e0 3 GVAr, avec un d\u00e9s\u00e9quilibre particuli\u00e8rement marqu\u00e9 dans le sud.<\/p>\n<p style=\"text-align: justify;\">REE reconna\u00eet \u00e9galement que ces actions ont permis de contr\u00f4ler la situation, mais au prix d\u2019une augmentation de la tension du syst\u00e8me.<\/p>\n<p style=\"text-align: justify;\"><strong>Analyse d\u00e9taill\u00e9e de l\u2019impact des mesures adopt\u00e9es<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li><strong>Renforcement du r\u00e9seau<\/strong> : la connexion de cinq lignes 400 kV a permis de r\u00e9duire les imp\u00e9dances, mais a \u00e9galement augment\u00e9 les flux de puissance r\u00e9active. Si cette puissance n\u2019est pas correctement absorb\u00e9e, elle peut entra\u00eener une augmentation dangereuse de la tension. AELEC souligne que la reconnexion de lignes rest\u00e9es inactives pendant plusieurs jours a aggrav\u00e9 la situation de surtension.<\/li>\n<li><strong>Modification de l\u2019interconnexion avec la France<\/strong> : le passage d\u2019un \u00e9change AC \u00e0 un \u00e9change DC a permis de stabiliser les premi\u00e8res oscillations, mais pourrait avoir r\u00e9duit la flexibilit\u00e9 du syst\u00e8me face aux perturbations ult\u00e9rieures. Le rapport d\u2019AELEC indique qu\u2019une analyse plus d\u00e9taill\u00e9e est n\u00e9cessaire pour \u00e9valuer pleinement son impact.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Malgr\u00e9 des signes de reprise du syst\u00e8me, la tension a continu\u00e9 d\u2019augmenter. Initialement dans les limites admissibles, elle a fini par les d\u00e9passer, sugg\u00e9rant que les mesures de contr\u00f4le \u00e9taient insuffisantes ou inadapt\u00e9es.<\/p>\n<p style=\"text-align: justify;\"><strong>Pourquoi la surtension n\u2019a-t-elle pas \u00e9t\u00e9 contenue ?<\/strong><\/p>\n<p style=\"text-align: justify;\">Le rapport du MITECO sugg\u00e8re trois causes possibles expliquant le manque de capacit\u00e9 automatique du syst\u00e8me \u00e0 g\u00e9rer la surtension :<\/p>\n<ol style=\"text-align: justify;\">\n<li><strong>D\u00e9faillance de planification<\/strong> : l\u2019op\u00e9rateur du syst\u00e8me (REE) n\u2019avait pas programm\u00e9 suffisamment de centrales conventionnelles connect\u00e9es pour r\u00e9guler la tension.<\/li>\n<li><strong>D\u00e9faillance d\u2019ex\u00e9cution<\/strong> : les centrales programm\u00e9es n\u2019ont pas rempli leur fonction, malgr\u00e9 leur disponibilit\u00e9.<\/li>\n<li><strong>Combinaison des deux<\/strong> : il n\u2019y avait pas suffisamment de centrales, et celles disponibles n\u2019ont pas correctement fonctionn\u00e9.<\/li>\n<\/ol>\n<p style=\"text-align: justify;\">Une divergence majeure appara\u00eet ici :<\/p>\n<ul style=\"text-align: justify;\">\n<li><strong>REE<\/strong> d\u00e9fend l\u2019id\u00e9e d\u2019une d\u00e9faillance d\u2019ex\u00e9cution : les centrales n\u2019ont pas r\u00e9pondu conform\u00e9ment \u00e0 la Proc\u00e9dure d\u2019Exploitation 7.4.<\/li>\n<li><strong>AELEC<\/strong> pointe plut\u00f4t une d\u00e9faillance de planification, soulignant que le nombre de groupes allou\u00e9s \u00e9tait le plus faible de l\u2019ann\u00e9e et concentr\u00e9 dans le nord, limitant ainsi leur efficacit\u00e9.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">Le rapport d\u2019AELEC insiste notamment sur le fait que REE a d\u00e9cid\u00e9 de ne pas remplacer une centrale \u00e0 cycle combin\u00e9 (CCGT) pr\u00e9vue le jour du black-out dans la zone sud, d\u00e9clar\u00e9e indisponible la veille au soir en raison d\u2019un incendie. REE r\u00e9pond toutefois que, malgr\u00e9 cette indisponibilit\u00e9, le syst\u00e8me restait s\u00e9curis\u00e9.<\/p>\n<p style=\"text-align: justify;\"><strong>Une d\u00e9connexion massive trop pr\u00e9coce ?<\/strong><\/p>\n<p style=\"text-align: justify;\">Le second grand sujet de d\u00e9bat concerne la d\u00e9connexion soudaine de plus de 2 000 MW de production en quelques secondes et sur diff\u00e9rentes installations.<\/p>\n<ul style=\"text-align: justify;\">\n<li><strong>MITECO<\/strong> et <strong>REE<\/strong> d\u00e9taillent la s\u00e9quence de ces d\u00e9connexions.<\/li>\n<li><strong>AELEC<\/strong> estime qu\u2019il doit exister une cause syst\u00e9mique expliquant ce comportement simultan\u00e9 et g\u00e9n\u00e9ralis\u00e9.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">\u00c0 12h32:57, un transformateur s\u2019est d\u00e9connect\u00e9 dans une sous-station de Grenade. REE affirme dans son rapport que cette d\u00e9connexion \u00e9tait incorrecte, car la tension sur le r\u00e9seau de transport restait dans les limites r\u00e9glementaires.<\/p>\n<p style=\"text-align: justify;\">\u00c0 12h33:16, soit \u00e0 peine 19 secondes plus tard, une autre d\u00e9connexion est survenue \u00e0 Badajoz. L\u00e0 encore, REE indique que les niveaux de tension \u00e9taient conformes aux marges \u00e9tablies.<\/p>\n<p style=\"text-align: justify;\">Ces d\u00e9connexions ont provoqu\u00e9 une nouvelle hausse de la tension du syst\u00e8me, la capacit\u00e9 d\u2019absorption de puissance r\u00e9active de ces g\u00e9n\u00e9rateurs ayant \u00e9t\u00e9 perdue, tout comme la circulation de puissance du sud vers le nord.<\/p>\n<p style=\"text-align: justify;\">L\u2019ensemble de ces \u00e9v\u00e9nements a conduit \u00e0 une perte en cascade de capacit\u00e9s de production. Cela a impliqu\u00e9 une perte simultan\u00e9e de la capacit\u00e9 dynamique de contr\u00f4le de tension et de l\u2019absorption de puissance r\u00e9active, alors m\u00eame que les technologies conventionnelles perdaient leur r\u00f4le de soutien, conduisant finalement \u00e0 un \u00ab z\u00e9ro \u00e9lectrique \u00bb du syst\u00e8me.<\/p>\n<p style=\"text-align: justify;\"><strong>Conclusion<\/strong><\/p>\n<p style=\"text-align: justify;\">Les trois rapports publi\u00e9s jusqu\u2019\u00e0 pr\u00e9sent s\u2019accordent pour souligner le caract\u00e8re multifactoriel du black-out, bien que chacun mette l\u2019accent sur diff\u00e9rents aspects en fonction du r\u00f4le et des comp\u00e9tences de l\u2019organisme \u00e9metteur.<\/p>\n<p style=\"text-align: justify;\">Alors que REE d\u00e9fend que la capacit\u00e9 du syst\u00e8me \u00e0 contr\u00f4ler la tension \u00e9tait suffisante, MITECO et AELEC estiment tous deux que cette capacit\u00e9 \u00e9tait la plus faible enregistr\u00e9e de toute l\u2019ann\u00e9e et la jugent clairement insuffisante.<\/p>\n<p style=\"text-align: justify;\">Par ailleurs, REE et MITECO affirment que certaines centrales n\u2019ont pas correctement appliqu\u00e9 la Proc\u00e9dure d\u2019Exploitation 7.4 relative au contr\u00f4le de tension sur le r\u00e9seau de transport, un point qu\u2019AELEC n\u2019aborde pas dans son rapport.<\/p>\n<p style=\"text-align: justify;\">En l\u2019absence de donn\u00e9es publi\u00e9es par l\u2019op\u00e9rateur du syst\u00e8me, AELEC \u00e9vite de se prononcer en d\u00e9tail sur le ph\u00e9nom\u00e8ne des d\u00e9connexions en cascade des installations de production. De son c\u00f4t\u00e9, REE consid\u00e8re que ces d\u00e9connexions se sont produites de mani\u00e8re incorrecte.<\/p>\n<p style=\"text-align: justify;\">Dans l\u2019attente des rapports d\u2019ENTSO-E et de la CNMC, tel est l\u2019\u00e9tat actuel de l\u2019analyse du black-out du 28 avril.<\/p>\n<p style=\"text-align: justify;\">Depuis Haya Energy Solutions, nous continuerons \u00e0 vous tenir inform\u00e9s de toute \u00e9volution pertinente.<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: right;\"><strong>Pablo Gandullo Romero<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Trois rapports analysent le black-out du 28 avril en Espagne : que r\u00e9v\u00e8lent-ils ? En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril. Le premier \u00e9mane du minist\u00e8re de la Transition \u00e9cologique et du D\u00e9fi d\u00e9mographique (MITECO) le 17 juin. Le lendemain, Red [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":17083,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[50,55,31],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Black-out du 28 avril : nouvelles informations - Haya Energy Solutions<\/title>\n<meta name=\"description\" content=\"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Black-out du 28 avril : nouvelles informations - Haya Energy Solutions\" \/>\n<meta property=\"og:description\" content=\"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\" \/>\n<meta property=\"og:site_name\" content=\"Haya Energy Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-19T14:13:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-19T14:20:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"853\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Pablo Gandullo Romero\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":[\"Article\",\"BlogPosting\"],\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\"},\"author\":{\"name\":\"Pablo Gandullo Romero\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/b6f3eda491e36101ce80514b24b58af8\"},\"headline\":\"Black-out de la p\u00e9ninsule Ib\u00e9rique du 28 avril : nouvelles informations\",\"datePublished\":\"2026-05-19T14:13:23+00:00\",\"dateModified\":\"2026-05-19T14:20:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\"},\"wordCount\":1604,\"publisher\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/#organization\"},\"image\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg\",\"articleSection\":[\"\u00c9nergie renouvelable\",\"Tendances \u00e9nerg\u00e9tiques\",\"Toutes les publications\"],\"inLanguage\":\"fr-FR\"},{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\",\"url\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\",\"name\":\"Black-out du 28 avril : nouvelles informations - Haya Energy Solutions\",\"isPartOf\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg\",\"datePublished\":\"2026-05-19T14:13:23+00:00\",\"dateModified\":\"2026-05-19T14:20:45+00:00\",\"description\":\"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.\",\"breadcrumb\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage\",\"url\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg\",\"contentUrl\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg\",\"width\":1280,\"height\":853},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/hayaenergy.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Black-out de la p\u00e9ninsule Ib\u00e9rique du 28 avril : nouvelles informations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#website\",\"url\":\"https:\/\/hayaenergy.com\/fr\/\",\"name\":\"Haya Energy Solutions\",\"description\":\"Providers of tailor-made solutions for your energy projects\",\"publisher\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/hayaenergy.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#organization\",\"name\":\"Haya Energy Solutions\",\"url\":\"https:\/\/hayaenergy.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2024\/02\/cropped-foto_cv-4.png\",\"contentUrl\":\"https:\/\/hayaenergy.com\/wp-content\/uploads\/2024\/02\/cropped-foto_cv-4.png\",\"width\":512,\"height\":512,\"caption\":\"Haya Energy Solutions\"},\"image\":{\"@id\":\"https:\/\/hayaenergy.com\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/b6f3eda491e36101ce80514b24b58af8\",\"name\":\"Pablo Gandullo Romero\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/33498bf4bad214579332e9e7c081421a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/33498bf4bad214579332e9e7c081421a?s=96&d=mm&r=g\",\"caption\":\"Pablo Gandullo Romero\"},\"url\":\"https:\/\/hayaenergy.com\/fr\/author\/p-gandullo\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Black-out du 28 avril : nouvelles informations - Haya Energy Solutions","description":"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/","og_locale":"fr_FR","og_type":"article","og_title":"Black-out du 28 avril : nouvelles informations - Haya Energy Solutions","og_description":"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.","og_url":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/","og_site_name":"Haya Energy Solutions","article_published_time":"2026-05-19T14:13:23+00:00","article_modified_time":"2026-05-19T14:20:45+00:00","og_image":[{"width":1280,"height":853,"url":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg","type":"image\/jpeg"}],"author":"Pablo Gandullo Romero","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":["Article","BlogPosting"],"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#article","isPartOf":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/"},"author":{"name":"Pablo Gandullo Romero","@id":"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/b6f3eda491e36101ce80514b24b58af8"},"headline":"Black-out de la p\u00e9ninsule Ib\u00e9rique du 28 avril : nouvelles informations","datePublished":"2026-05-19T14:13:23+00:00","dateModified":"2026-05-19T14:20:45+00:00","mainEntityOfPage":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/"},"wordCount":1604,"publisher":{"@id":"https:\/\/hayaenergy.com\/fr\/#organization"},"image":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage"},"thumbnailUrl":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg","articleSection":["\u00c9nergie renouvelable","Tendances \u00e9nerg\u00e9tiques","Toutes les publications"],"inLanguage":"fr-FR"},{"@type":["WebPage","ItemPage"],"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/","url":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/","name":"Black-out du 28 avril : nouvelles informations - Haya Energy Solutions","isPartOf":{"@id":"https:\/\/hayaenergy.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage"},"image":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage"},"thumbnailUrl":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg","datePublished":"2026-05-19T14:13:23+00:00","dateModified":"2026-05-19T14:20:45+00:00","description":"En seulement une semaine, trois rapports cl\u00e9s ont \u00e9t\u00e9 publi\u00e9s concernant le black-out majeur qui a affect\u00e9 l\u2019Espagne le 28 avril.","breadcrumb":{"@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#primaryimage","url":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg","contentUrl":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2025\/05\/candle-2038736_1280.jpg","width":1280,"height":853},{"@type":"BreadcrumbList","@id":"https:\/\/hayaenergy.com\/fr\/black-out-de-la-peninsule-iberique-du-28-avril-nouvelles-informations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/hayaenergy.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Black-out de la p\u00e9ninsule Ib\u00e9rique du 28 avril : nouvelles informations"}]},{"@type":"WebSite","@id":"https:\/\/hayaenergy.com\/fr\/#website","url":"https:\/\/hayaenergy.com\/fr\/","name":"Haya Energy Solutions","description":"Providers of tailor-made solutions for your energy projects","publisher":{"@id":"https:\/\/hayaenergy.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hayaenergy.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/hayaenergy.com\/fr\/#organization","name":"Haya Energy Solutions","url":"https:\/\/hayaenergy.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hayaenergy.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2024\/02\/cropped-foto_cv-4.png","contentUrl":"https:\/\/hayaenergy.com\/wp-content\/uploads\/2024\/02\/cropped-foto_cv-4.png","width":512,"height":512,"caption":"Haya Energy Solutions"},"image":{"@id":"https:\/\/hayaenergy.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/b6f3eda491e36101ce80514b24b58af8","name":"Pablo Gandullo Romero","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hayaenergy.com\/fr\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/33498bf4bad214579332e9e7c081421a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/33498bf4bad214579332e9e7c081421a?s=96&d=mm&r=g","caption":"Pablo Gandullo Romero"},"url":"https:\/\/hayaenergy.com\/fr\/author\/p-gandullo\/"}]}},"_links":{"self":[{"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/posts\/20443"}],"collection":[{"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/comments?post=20443"}],"version-history":[{"count":2,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/posts\/20443\/revisions"}],"predecessor-version":[{"id":20445,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/posts\/20443\/revisions\/20445"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/media\/17083"}],"wp:attachment":[{"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/media?parent=20443"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/categories?post=20443"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hayaenergy.com\/fr\/wp-json\/wp\/v2\/tags?post=20443"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}